1. Range hood

Before installation and construction, the installation position and pipeline direction of the machine shall be determined, and the construction shall be carried out after confirmation by the user.If the installation location and pipeline direction do not meet the requirements or the user puts forward reasonable requirements, the materials and labor costs that need to be reworked shall be borne by the installation unit itself;

If want to drill hole in the wall in the construction, answer to ask user wall is to have other pipeline inside, wait like line of electric wire, phone line and closed-circuit TV, after classics user confirms, construct again.Otherwise all consequences arising therefrom shall be borne by the installation unit;

When installing the smoke pipe of the smoke machine, first put the sealing pad of the air pipe seat on the air outlet of the whole machine, fasten the air pipe seat on the air outlet with four screws, and then lead the smoke pipe sleeve to the open hole on the wall outside the air outlet.


2, kitchen is provided

Embedded kitchen should be according to the size of the mounting hole template in the packaging box or the size provided, the embedded hole should be opened on the kitchen counter surface, the bottom of the kitchen cabinet embedded kitchen should be reserved not less than 100cm2 air inlet to retain the free air flow at the bottom of the kitchen;

When opening the hole, pay attention to the position of the cooker above 15cm from the wall or other articles, and the top should have a space above 100cm.


3. Disinfection cabinet

When embedded disinfection ark is in ambry and ambry combination, should be in ambry to install the place to suit to install the air that is communicated with disinfection ark to enter platoon tuyere, in order to ensure air to enter platoon good.Note: in any inconspicuous part of the cabinet, an air vent with an area no less than 50cm2 should be opened behind the mounting hole of the disinfection cabinet.

Embedded disinfection cabinet should be installed smoothly in a place that is convenient for operation and maintenance and firm (without tilting). It should keep a safe distance of more than 15cm from the burner and high-temperature open fire, away from water source!


4. Water heater

Before installation and construction, the installation position and pipeline direction of the machine shall be determined, and the construction shall be carried out after confirmation by the user.If the installation location and pipeline direction do not meet the requirements or the user puts forward reasonable requirements, the materials and labor costs that need to be reworked shall be borne by the installation unit itself;

Water heater installation in an airtight room is strictly prohibited to use, must be installed in well ventilated and volume is greater than 7.5 m3 in the room, when used for water heater consumes huge amounts of oxygen, so the room should be designed area of 0.06 m2 more air inlet and exhaust fan (note: exhaust fan and air inlet must be with the outside room), and be sure to install smoke tube;

Install the water heater 50cm away from the surrounding walls and ceiling, away from stoves, flammable and hazardous materials;

It is advisable to install the water heater at a height of about 1.5m so that it can be easily observed by the human eye.